Home ProductsThermal Shock Test Chamber

Air Conditioning System Thermal Shock Test Chamber Cold Rolled Heat Exchanger

Certification
China Guangdong Sanwood Technology Co.,Ltd certification
China Guangdong Sanwood Technology Co.,Ltd certification
I'm Online Chat Now

Air Conditioning System Thermal Shock Test Chamber Cold Rolled Heat Exchanger

Air Conditioning System Thermal Shock Test Chamber Cold Rolled Heat Exchanger
Air Conditioning System Thermal Shock Test Chamber Cold Rolled Heat Exchanger

Large Image :  Air Conditioning System Thermal Shock Test Chamber Cold Rolled Heat Exchanger

Product Details:
Place of Origin: GUANGDONG ,CHINA
Brand Name: SANWOOD
Certification: CE AND ISO
Model Number: SM-3P-A
Payment & Shipping Terms:
Minimum Order Quantity: 1 pcs
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 4 to 5 weeks
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 60 sets per Month

Air Conditioning System Thermal Shock Test Chamber Cold Rolled Heat Exchanger

Description
Product Name: Three Zone Thermal Shock Chamber Model: SM-202-3P-B
Nner Volume: 202L Internal Dimension: W650*D670*H460mm
External Dimension: W1550*D1800*H1900mm Pre-heating Temperature: ﹢60 ℃ ~ ﹢180 ℃ ∕ 40 Min
Pre-cooling Temperature: ﹣10 ℃ ~ ﹣55 ℃ ∕ 40 Min
High Light:

thermal test chamber

,

thermal cycling chamber

       Cold rolled heat exchanger 3 Zone Air to Air Thermal Shock Test Chamber

 

1. Description:

 

Environmental Test Chamber Cold-rolled heat exchanger Thermal Shock Chamber adpots low temperature and high temperature accumulation slot,after open damper, it will take hot and cold temperature in stored groove import test slots so as to achieve rapid temperature concussion effect,with balance temperature control system (BTC) , special design of air circulation system, the way to control SSR in P.I.D.make the system add heat is equal to the quantity of heat loss.

 

 

Hot and cold impact test box operation: pretreatment, the initial inspection, test, recovery,

 

 

Air conditioning system


1.The air control: forced ventilation circulation, balance thermostat method (BTC). This method not only refers to the case of the cooling system for continuous operation, the control system according to the temperature set point of the heater to control the output of the results by automatically calculating PID output, and ultimately achieve a dynamic equilibrium.

 

2.Air circulating means: built between the air circulation fan duct and the long axis of stainless steel, the use of energy efficient refrigerators and regulation system, by effective and efficient heat exchange ventilator, to achieve the purpose of the temperature change. By adjustable air outlet adjusting bolt, thereby significantly improving the chamber temperature uniformity;

 

3. The air cooling method: multi-stage diaphragm air heat exchanger.

 

4 Air heating: Watkins quality nickel chrome electric heater.

 

5. Specification

 

Pre-heating Temperature ﹢60 ℃ ~ ﹢180 ℃ ∕ 40 min

Pre-cooling Temperature

Temperature uniformity

Temperature fluctuation

High Temperature shock range

Low Temperature shock range

Temperature recovery Time

Damper open time

Test load

﹣10 ℃ ~ ﹣55 ℃ ∕ 40 min

±1.0℃

±1.0℃

﹢60 ℃ ~ ﹢150 ℃≤1℃

﹣10 ℃ ~ ﹣40℃

-55℃~+150℃/ Within 5 minutes

Within 3 seconds

10kg

 

Model SM-50-3P-A SM-80-3P-A SM-100-3P-A SM-150-3P-A SM-200-3P-A SM-300-3P-A SM-500-3P-A
Temperature Temperature impact
range
-70℃~150℃ (A:-45℃~150℃;B:-70℃~150℃;)
Temperature
fluctuation
±1.0℃
Low temperature
precooling time
25.0℃~-70.0℃ Within 60 mins 1.0~3.0℃/min
High temperature
preheating time
25.0℃~200.0℃ Within 60 mins 3.0~7.0℃/min
Temperature
conversion time
3S
Temperature
recovery time
Within 5 mins Within 10 mins
Material /
components
Internal material Stainless steel(SUS304)
External material Cold rolled steel sheet / powder spraying
Heat insulating
material
100mm thickness polyurethane plate+10mm thickness mineral wool
Fan Centrifugal blower
Compressor France Tecumseh, Germany Bock, Germany Bitzer
Condenser Air cooling, water cooling water cooling
Refrigerant R404A,R23,R508
Evaporator Fin - and - Tube Heat Exchanger
Heater Nickel chromium alloy heating wire
Size Interior size(mm)
W*H*D

350*400

*350

400*500

*400

500*500

*400

500*600

*500

650*460

*670

960*460

*670

960*650

*800

Outer size(mm)
W*H*D

1400*1750

*1750

1450*1850

*1800

1550*1850

*1800

1550*2050

*2050

1700*2000

*2200

2050*2000

*2250

2050*2150

*2450

Volume(L) 50L 80L 100L 150L 200L 300L 500L
Operating ambient temperature +5 ~ 35℃
Power supply 380V AC 50/60Hz 380V AC 50/60Hz 380V AC
50/60Hz
380V AC
50/60Hz
380V AC
50/60Hz
380V AC
50/60Hz
380V AC
50/60Hz
Controller SANWOOD SH5600:Equipped with RS232 port;(7.0 inch controller) USB data export )

 

Product Catalog:

Three-zone Thermal Shock Test Chamber.pdf

 

Contact Details
Guangdong Sanwood Technology Co.,Ltd

Contact Person: Nancy Shen

Tel: +86-769-81182799

Send your inquiry directly to us (0 / 3000)